How backflow occurs
Backflow occurs when the public sewer network has to take in more water than it can carry away – for example during heavy rain or snowmelt. The wastewater backs up and finds its way out through the lowest outlets, usually floor drains, toilets or washbasins in the basement.
Without protection, wastewater then escapes uncontrollably into the lower floors. The backflow level, usually the top edge of the road, marks the limit up to which water can theoretically back up.
What types of backflow protection are there?
The most common are backflow valves (non-return flaps), which close automatically when backflow occurs, and lifting stations, which pump wastewater from low-lying rooms above the backflow level. Which solution is suitable depends on how the rooms are used and the type of wastewater.
For wastewater containing faeces from rooms in permanent use, lifting stations or special backflow valves with two flaps are generally required.
Maintenance and inspection
Backflow protection only protects if it works perfectly. Flaps and seals must be checked, cleaned and tested for free movement regularly, as deposits can jam the valve.
Karo Kanaltechnik checks existing backflow protection, cleans it and advises on choosing and installing the right solution.
During a thunderstorm, a homeowner in Bülach saw wastewater pushing up through the basement drain. Karo Kanaltechnik assesses the situation and recommends a backflow valve for the affected pipe. During the next heavy rainfall, the basement stays dry because the flap reliably keeps the backflow out.