What damage occurs in manholes?
Typical damage includes leaking joints and connections, corroded or sanding concrete walls, cracks, defective drainage channels (benching) and damaged climbing aids. Groundwater enters or wastewater escapes through leaking points.
The manhole cover and the upper cone section are also frequently affected, because they are subjected to heavy stress from traffic and frost. Ingress of infiltration water also puts an unnecessary load on the treatment plant.
How is a manhole rehabilitated?
After cleaning and inspection, the appropriate method is chosen. Leaking joints are grouted or sealed, damaged walls receive a mineral or synthetic coating, and badly attacked manholes are lined with an internal system.
The channel, i.e. the drainage channel in the manhole floor, is reprofiled if necessary to optimise the flow. Climbing aids and covers are replaced where they endanger safety.
When does manhole rehabilitation make sense?
Rehabilitation is advisable as soon as infiltration water gets in, wastewater escapes, the concrete is visibly corroded or structural stability is at risk. Such defects are often discovered during manhole cleaning or a condition assessment.
Timely rehabilitation is considerably cheaper than building a completely new manhole. It also protects the groundwater and keeps the installation legally compliant and operationally reliable.
Advantages of manhole rehabilitation
Rehabilitation restores tightness and structural strength without the manhole having to be removed and rebuilt. This saves costs, time and effort and reduces the impact on the surroundings.
Coatings and linings permanently protect the concrete against corrosion by aggressive wastewater constituents. This extends the service life of the manhole by many years.
In an inspection chamber near Chur, infiltration water enters through leaking joints when the groundwater level is high and overloads the pump. Instead of replacing the manhole, the joints are grouted and the walls are given a mineral coating. The manhole is tight again and the pump runs in normal operation.