GlossaryDrainage technical term

Backflow level

Also: Backflow height

The backflow level is the height up to which wastewater from the public sewer can push back into the house drains during heavy rain or a blockage. If you know where it is, you also know which rooms in the cellar are at risk and where a backflow protection device or a lifting station is needed.

Karo Kanaltechnik job at an underground car park entrance – a typical area below the backflow level

In brief

The backflow level is the highest level up to which wastewater from the public sewer system can back up into a property. In Switzerland, it usually corresponds to the top edge of the road at the connection point; the municipality sets it bindingly. Every drain that lies lower – in the cellar or underground car park, for example – must be protected against backflow.

What is the backflow level?

The backflow level describes an imaginary horizontal line: water can build up in a sewer network to this height when more wastewater arrives than can drain away. Because a property’s pipes are connected to the public sewer system, the water also rises in the house drains up to this height, following the principle of communicating vessels.

If a drain – a floor drain in the laundry room, a shower in the basement or a washbasin in the hobby room – lies below the backflow level, the wastewater comes out there. That is exactly why the backflow level is the central reference point when it comes to protecting cellars, underground garages and basements against flooding.

Where is the backflow level in Switzerland?

In Switzerland, the backflow level is generally set at the top edge of the road at the point where the property connects to the public sewer system. The reason is simple: if a sewer backs up completely, the water comes out at the manhole covers in the road at the latest and cannot rise any higher.

What is binding, however, is always the municipality’s specification, usually in the drainage regulations or in the permit documents for the property drainage. On slopes, with low-lying roads or in areas with known overloading, the municipality can prescribe different heights. Anyone building or converting should therefore ask the building authority for the relevant height at an early stage.

Which drains have to be protected against backflow?

The basic rule is that every drainage point below the backflow level needs protection. This includes floor drains in the cellar and laundry room, showers, toilets and washing machine connections in the basement, drains in light wells, cellar stairwells and garage driveways, and channels in underground car parks.

Drains above the backflow level, on the other hand, drain by gravity and need no protection. Property drainage planning to SN 592 000 therefore draws a clear distinction between pipes above and below this height. If the two areas are joined without due thought, a single unprotected drain can put the whole basement at risk.

Protection below the backflow level: backflow valve or lifting station

There are two basic principles of protection. A backflow valve to SN EN 13564 – often called a backflow flap – closes the pipe as soon as water pushes back. It is suitable for rooms of secondary use and for wastewater free of faeces, but requires that nobody discharges water into the protected drains during backflow.

The safer solution is a lifting station. It pumps the wastewater through a backflow loop that is taken above the backflow level, and so drains reliably even during backflow. For toilets and living spaces in the basement, it is generally the professionally correct choice. Both systems must be checked and serviced regularly so that they work when it matters.

Why backflow is becoming an issue more and more often

Short, violent thunderstorms repeatedly overload sewer networks. In many municipalities, the sewer system was sized for lower rainfall and fewer sealed surfaces than exist today. If a partly blocked house drain or a full silt trap is added to this, the water in the cellar rises faster than expected.

Backflow damage is often expensive for owners, because wet floors, walls and stored items are affected. Whether an insurer pays often depends on whether a prescribed backflow protection device was in place and working. That makes knowing your own backflow level a very practical question.

How to check your property

The first step is the drainage plan: it shows which drains are in the basement and how they are connected. If there is no up-to-date plan, the route of the pipes can be reconstructed with a CCTV drain survey and pipe locating. This also shows whether existing backflow valves are still there and move freely.

Regular cleaning of the underground drains and manholes is also worthwhile. Deposits narrow the cross-section, so that water backs up even in moderate rain. Combining cleaning, inspection and servicing of the backflow protection significantly reduces the risk of a flooded cellar.

Practical example

In an apartment building in Dietikon, there was water in the laundry room and the bicycle storage room after a summer thunderstorm. The investigation showed that the floor drain lay well below the backflow level, and the backflow valve in the underground drain was blocked with deposits and no longer closed. Karo cleaned the pipe with high-pressure water, checked the valve by camera and recommended that the property management replace the valve and have it serviced every year. During the next heavy rain, the basement stayed dry.

Backflow level: frequently asked questions

How do I find out where the backflow level of my property is?+

What counts is the municipality’s specification, which you can find at the building authority or in the drainage regulations. In most cases, the backflow level corresponds to the top edge of the road at your property’s connection point. The drainage plan also shows which drains lie below it.

Is a backflow valve enough?+

For wastewater free of faeces from rooms of secondary use, it often is. For toilets or living spaces in the basement, a lifting station with a backflow loop is usually the safer solution, because it can drain even during backflow. Professional planning is what matters.

What happens if drains below the backflow level are unprotected?+

When backflow occurs in the public sewer, the wastewater in the house drains rises up to the backflow level and comes out at the lowest unprotected drain. Typical consequences are flooded cellars, laundry rooms and underground car parks with dirty wastewater.

How often should backflow protection be serviced?+

Backflow valves and lifting stations should be checked regularly according to the manufacturer’s instructions, but at least once a year. The flaps are checked to make sure they move freely, deposits are removed and seals are inspected. Cleaning the pipe beforehand makes the check easier.

Backflow level in your region?

We are there for you across German-speaking Switzerland – fast, clean, with a 24/7 emergency service.