What is SN 592000?
SN 592000 bears the title «Installations for property drainage». It describes how the private wastewater installations of a property should be planned, built and operated: the pipes inside the building, the underground drains in the ground, the manholes, separators and pumping installations, and the handover to the public sewer or to an infiltration system.
The abbreviation SN stands for Swiss standard (Schweizer Norm). SN 592000 is therefore not a law, but the recognised state of the art that planners, plumbers, builders and drainage specialists follow. It becomes binding when cantons, municipalities or clients (building owners) refer to it in regulations, permits or works contracts. For new buildings and conversions requiring a permit, this is the normal case in practice.
In everyday use, you will come across both spellings, «SN 592000» and «SN 592 000». Both refer to the same document. Anyone who needs it for a project can purchase the standard from the suissetec shop or from the VSA.
Who publishes the standard and which edition applies?
SN 592000 is published jointly by the VSA, the Swiss Association of Wastewater and Water Protection Professionals, and by suissetec, the Swiss-Liechtenstein Building Technology Association. This combination is no coincidence: property drainage lies exactly at the interface between building services inside the house and urban drainage outside the house.
The standard is revised at longer intervals. For a long time, the 2012 edition was authoritative; SN 592000:2024 has since been published. Which edition applies to a specific building project depends on when the permit was issued and on the requirements of the municipality. For existing installations, a new edition does not automatically mean that retrofitting is required – that only arises with a conversion, a renovation or an official order.
In addition to the standard, the associations publish information sheets and explanatory notes. For pipes inside buildings, the European standard series SN EN 12056 also applies, and SN EN 1610 applies to the laying and testing of buried pipes. SN 592000 brings these rules together into an overall picture for the Swiss property.
What does SN 592000 cover?
The standard covers the entire life cycle of a property drainage system. Planning is about the drainage system – that is, whether foul water and rainwater are discharged together in a combined system or separately in a separate system – about sizing the pipes, gradient, choice of materials, routing and the question of where unpolluted rainwater can infiltrate or be retained.
For the construction phase, it describes how pipes are laid, manholes are set, connections are formed and installations such as separators or lifting stations are fitted. This also includes the tests before commissioning, in particular proof of leak-tightness for new buildings and at acceptance, as well as documenting the completed installation in plans.
For operation, the standard requires the installation to remain accessible, inspectable and cleanable. Pipes must be arranged so that they can be flushed and surveyed with a camera. This is exactly where maintenance, drain cleaning and the CCTV drain survey come in: an installation planned in accordance with SN 592000 can be kept in good condition for decades with reasonable effort.
Specific figures – such as minimum gradients, nominal diameters or manhole spacing – are set out in the standard itself and depend on the type of pipe and the situation. For planning, the current text of the standard should always be consulted, not a second-hand summary.
Key terms in the standard
Backflow level: the height up to which wastewater from the public sewer can back up into the building's pipes. In Switzerland, it is usually at the top edge of the road at the connection point; the municipality sets it bindingly. Drains below this height need a backflow stop or a lifting station.
Inspection chamber: the access to the underground drain at changes of direction, junctions and before the connection to the public sewer. It is used for cleaning, inspection and testing. The standard ensures that there are enough of these access points and that they can be reached.
Underground drain: the collecting pipe laid in the ground or beneath the floor slab, which takes wastewater from the soil stacks and carries it to the house connection. Because it is hardly accessible after construction, gradient, bedding and leak-tightness are particularly important here.
Ventilation: the extension of the soil stacks above the roof. It balances out pressure fluctuations, protects the water seal in the traps and carries away sewer gases. If it is missing or blocked, drains gurgle and there is a sewer smell.
The standard also uses terms such as foul wastewater, unpolluted wastewater, connecting pipe, cleaning opening, silt trap and separator. Anyone who knows these words will understand drainage plans, quotes and inspection reports much better.
What does SN 592000 mean for property owners?
For owners, the standard makes itself felt mainly on three occasions. For new builds or conversions, the municipality requires a drainage application and carries out the acceptance of the installation; planners and contractors must work in accordance with the standard. In a renovation, the standard is the yardstick against which the condition and the measures are measured. And when a property is bought or sold, a comparison with the state of the art shows whether hidden defects are to be expected.
Responsibility for private property drainage generally lies with the owner. They must ensure that the installation is watertight, works properly and is maintained. The exact boundary with the public sewer and the individual obligations are set out in the municipality's wastewater or drainage regulations.
In practice, this means: keep the drainage plan and update it after conversions, keep inspection chambers accessible, have backflow protection devices and lifting stations serviced and have the pipes cleaned and inspected by camera at sensible intervals. Anyone who does this not only meets the expectations of the standard, but also avoids expensive consequential damage from backflow, root ingress or leaking pipes.
Testing, documentation and acceptance
For new or rehabilitated pipes, leak-tightness is proven before acceptance. The test is carried out with water or air using the procedures of SN EN 1610, either from manhole to manhole or section by section. The test report belongs in the property's documentation together with the as-built plans.
For the condition of existing pipes, the CCTV drain survey is the most important tool. The findings are coded in accordance with SN EN 13508-2, so that cracks, displacements, deposits or root ingress are described uniformly and read in the same way by planners, municipalities and insurers. These data form the basis of a condition assessment with clear priorities.
In this context, Karo Kanaltechnik carries out the work on the existing or newly laid pipe: cleaning with chemical-free high-pressure water jetting at up to 200 bar, a camera survey with documentation in accordance with SN EN 13508-2, leak-tightness testing and condition assessment. Planning the drainage application itself remains the job of the planner or plumber.
Common deviations from the standard in older properties
Many properties were built long before the current edition. Typical deviations from today's state of the art that can come to light during a camera survey are: missing or covered-over inspection chambers, underground drains with too little gradient or a reverse gradient, unprotected drains in the basement below the backflow level, ventilation pipes sealed off during loft conversions, or rainwater discharged into the foul water pipe even though the municipality operates a separate system.
Such findings do not automatically mean that construction work is needed immediately. They are, however, a good reason to give property drainage specific thought at the next conversion, during landscaping or before a sale. A camera survey with a condition report provides the basis for this and shows which measures are urgent and which can wait.
In a single-family home in the Winterthur area, the basement was to be converted into a living space with a shower. For the building application, the municipality required information on the property drainage. The plumber commissioned for the job found that the existing drainage plan no longer matched what was actually in place. Karo cleaned the underground drain with high-pressure jetting, surveyed it with the camera, located the route of the pipe and documented the findings in accordance with SN EN 13508-2. This revealed that the new shower would be below the backflow level. Under SN 592000, such a drain must be protected against backflow; the planner provided a lifting station for this. After the conversion, a leak-tightness test proved the new pipe sections for acceptance.
