What is infiltration water?
In urban drainage, infiltration water (also called extraneous water) is water that is clean and therefore would not actually need to flow to the wastewater treatment plant (WWTP), but still gets there via the sewer system. It is not foul water from the kitchen, bathroom or toilet, nor rainwater from roofs and paved areas, but unpolluted water that occurs continuously or over long periods.
Specialists distinguish between extraneous water that penetrates from outside through damage – infiltration in the narrower sense – and extraneous water that is introduced via wrong connections. Both have the same effect: more water flows in the pipe than the use of the property would explain, and this water is pumped and treated at great expense, even though there is no reason to do so.
Where does infiltration water come from?
The most common source is groundwater which, when the water table is high or after heavy rain, seeps into the pipe through cracks, leaking joints, poorly made connections and porous manhole walls. The older and more damaged the pipe network, the greater the share. Deep-lying underground drains on slopes and in areas with perched water are particularly affected.
Other sources are misconnections: land drains and drainage around the house, spring catchments, fountain overflows or cooling water that are connected to the foul sewer instead of the rainwater sewer or an infiltration system. Such connections often date from times when the combined system was standard and were never corrected during later renovations.
Why infiltration water is a problem
Infiltration water takes up space in the sewers that is then missing in wet weather. The consequences are more frequent overflows of combined wastewater into watercourses and a higher risk of backflow in properties. At the same time it dilutes the wastewater at the WWTP, which can impair treatment performance and increases the energy needed for pumping stations and treatment.
Swiss water protection legislation therefore requires that unpolluted wastewater be allowed to soak away or be discharged into a watercourse wherever possible, and that continuously occurring infiltration water does not reach the central WWTP. Many municipalities set out measures to reduce infiltration water in the general drainage plan (GEP, Genereller Entwässerungsplan) and call on owners to check their private pipes and correct misconnections.
How to find infiltration water
A first indication is flow in the foul water manhole in dry weather and at times when nobody is using water – at night, for example. If clear water is flowing then, it rarely comes from the household. Measurements by the municipality also often show in which pipe sections the night-time flow is unusually high.
The exact cause is revealed by a CCTV drain survey: the camera shows water penetrating at cracks, joints and connections. Misconnections can be proven with a smoke test or with dye tests, which show where water fed into the system reappears. Finally, a leak-tightness test proves whether a pipe is watertight again after rehabilitation.
Eliminating infiltration water
If groundwater penetrates through damage, the pipe is rehabilitated. Individual leaks can be sealed without digging using a patch liner, continuously damaged sections with a CIPP liner. Leaking manholes are coated or lined. This not only makes the pipe watertight against infiltration water, but also prevents wastewater from escaping into the ground.
Misconnections are rerouted: the land drain or fountain overflow is separated from the foul sewer and connected to the rainwater pipe or to an infiltration system, provided the municipality permits this. Which solution is allowed is decided by the municipal wastewater regulations or the responsible authority – which is why it pays to clarify this before the work is carried out.
A municipality in the Zurich Oberland noticed unusually high night-time flow in one neighbourhood and asked the owners to have their pipes checked. At a single-family home from the 1970s, the CCTV drain survey showed that the land drain around the house discharged directly into the foul water underground drain and that groundwater was also penetrating at two leaking joints. The joints were sealed without digging using patch liners, and the drainage was reconnected to the rainwater manhole. A leak-tightness test then confirmed that the pipe was watertight.