GlossaryDrainage technical term

Smoke test

Also: smoke testing, smoke trial, fog test

A smoke test is a method in which non-toxic artificial smoke is blown into a wastewater pipe with a blower. Wherever the smoke comes out again, the pipe is open, leaking or connected differently than assumed. This makes hidden connections and damage visible in a short time – without digging.

Karo Kanaltechnik service vehicle in front of a new building for a smoke test of the pipes

In brief

In a smoke test, a blower blows non-toxic artificial smoke into a wastewater pipe. The smoke rises wherever the pipe is leaking or connections exist – at cracks, manholes, drains, gutters or in the garden. This is how misconnections, sources of odours and rat entry points are found. It does not replace a standardised proof of leak-tightness.

What is a smoke test?

The smoke test is a simple but very effective diagnostic method. A smoke generator produces a dense, clearly visible smoke, similar to the kind used on stages. A blower pushes this smoke into the pipe via a manhole or a rodding eye, putting the pipe under slight positive pressure.

The smoke spreads through all parts of the pipework connected to the injection point. Wherever it finds a way out, it rises visibly: from gutters, floor drains, manhole covers, joints in the surfacing or from the lawn above a damaged pipe. A technician observes and documents the exit points.

What the smoke test is used for

One main area of use is tracking down misconnections. In a separate system, foul water and rainwater must be drained away separately. If smoke is blown into the foul sewer and rises from a rainwater downpipe, the roof drainage is wrongly connected – or vice versa. Without testing, such faults often remain undetected for decades.

The smoke test is just as helpful for unexplained odours in the building. If smoke comes out of a dried-out water seal trap, a leaking pipe joint in the basement or an open pipe behind a panel, the source of the odour has been found. Gaps through which rats get from the sewer into the building can also be located this way.

How a smoke test is carried out

Before the test, residents, neighbours and – for larger tests in public areas – the relevant authorities are informed if necessary, so that rising smoke is not reported as a fire. Windows near drains are closed, and the water seal traps in the building are checked and topped up with water if needed.

The smoke is then blown in while the team systematically walks round the property and photographs each exit point and marks it on the drawing. The smoke used is harmless to people, animals and plants and leaves no residue. Depending on the size of the installation, the actual test often takes only a short time.

Limits of the smoke test

The smoke test shows where connections or larger leaks exist. However, it is no substitute for a standardised leak-tightness test with air or water to SN EN 1610, which provides measurable proof for new builds, rehabilitation or when requested by the municipality. Smaller leaks deep in the ground do not necessarily show up on the surface.

Pipes that are under water or blocked by deposits also do not let the smoke through. That is why the smoke test is usually combined with cleaning and a CCTV drain survey: the smoke shows where something is wrong, the camera shows exactly what is going on.

From the exit point to the solution

Once a misconnection has been found, the affected pipe is reconnected to the correct system – usually with minor excavation work. Depending on the findings, leaks in pipes are rehabilitated without digging using a patch liner or CIPP liner, and defective manholes are coated. Dried-out or missing water seal traps are replaced or retrofitted.

Sealing open pipe ends and installing a rat barrier in the underground drain help against rats. After the measures, a second smoke test can confirm that smoke no longer escapes at unwanted points. For municipalities, the result is documented in a report with photos and a drawing.

Practical example

In a terraced housing estate in Wetzikon, several basements regularly smelled of sewage, even though all the drains were clean. During the smoke test, the smoke came out in one house from an unused old laundry room pipe sealed only with adhesive tape, and in another from a leaking connection behind the basement panelling. In addition, smoke rose from two rainwater downpipes – a misconnection to the foul sewer. The open pipe was properly sealed, the connection rehabilitated and the downpipes reconnected to the rainwater pipe.

Smoke test: frequently asked questions

Is the smoke used in a smoke test toxic?+

No. Artificial smoke of the kind also used on stages is used. It is harmless to people, animals and plants and leaves no residue. Residents are nevertheless informed in advance so that nobody thinks there is a fire.

Does the smoke test replace a leak-tightness test?+

No. The smoke test shows connections and larger leaks, but does not provide measurable proof. For that, a leak-tightness test with air or water to SN EN 1610 is required.

Does the smoke test find misconnections?+

Yes, that is one of its main purposes. If smoke blown into the foul sewer comes out of a rainwater downpipe or a yard drain, that outlet is wrongly connected. The result is documented with photos and a drawing.

Does a smoke test help with drain smells?+

It helps to find the cause. The smoke shows where sewer gases get into the building – for example via dried-out traps, leaking joints or open pipe ends. Targeted sealing can then be carried out.

Smoke test in your region?

We are there for you across German-speaking Switzerland – fast, clean, with a 24/7 emergency service.