What is a smoke test?
The smoke test is a simple but very effective diagnostic method. A smoke generator produces a dense, clearly visible smoke, similar to the kind used on stages. A blower pushes this smoke into the pipe via a manhole or a rodding eye, putting the pipe under slight positive pressure.
The smoke spreads through all parts of the pipework connected to the injection point. Wherever it finds a way out, it rises visibly: from gutters, floor drains, manhole covers, joints in the surfacing or from the lawn above a damaged pipe. A technician observes and documents the exit points.
What the smoke test is used for
One main area of use is tracking down misconnections. In a separate system, foul water and rainwater must be drained away separately. If smoke is blown into the foul sewer and rises from a rainwater downpipe, the roof drainage is wrongly connected – or vice versa. Without testing, such faults often remain undetected for decades.
The smoke test is just as helpful for unexplained odours in the building. If smoke comes out of a dried-out water seal trap, a leaking pipe joint in the basement or an open pipe behind a panel, the source of the odour has been found. Gaps through which rats get from the sewer into the building can also be located this way.
How a smoke test is carried out
Before the test, residents, neighbours and – for larger tests in public areas – the relevant authorities are informed if necessary, so that rising smoke is not reported as a fire. Windows near drains are closed, and the water seal traps in the building are checked and topped up with water if needed.
The smoke is then blown in while the team systematically walks round the property and photographs each exit point and marks it on the drawing. The smoke used is harmless to people, animals and plants and leaves no residue. Depending on the size of the installation, the actual test often takes only a short time.
Limits of the smoke test
The smoke test shows where connections or larger leaks exist. However, it is no substitute for a standardised leak-tightness test with air or water to SN EN 1610, which provides measurable proof for new builds, rehabilitation or when requested by the municipality. Smaller leaks deep in the ground do not necessarily show up on the surface.
Pipes that are under water or blocked by deposits also do not let the smoke through. That is why the smoke test is usually combined with cleaning and a CCTV drain survey: the smoke shows where something is wrong, the camera shows exactly what is going on.
From the exit point to the solution
Once a misconnection has been found, the affected pipe is reconnected to the correct system – usually with minor excavation work. Depending on the findings, leaks in pipes are rehabilitated without digging using a patch liner or CIPP liner, and defective manholes are coated. Dried-out or missing water seal traps are replaced or retrofitted.
Sealing open pipe ends and installing a rat barrier in the underground drain help against rats. After the measures, a second smoke test can confirm that smoke no longer escapes at unwanted points. For municipalities, the result is documented in a report with photos and a drawing.
In a terraced housing estate in Wetzikon, several basements regularly smelled of sewage, even though all the drains were clean. During the smoke test, the smoke came out in one house from an unused old laundry room pipe sealed only with adhesive tape, and in another from a leaking connection behind the basement panelling. In addition, smoke rose from two rainwater downpipes – a misconnection to the foul sewer. The open pipe was properly sealed, the connection rehabilitated and the downpipes reconnected to the rainwater pipe.