What does retention mean in drainage?
When rain falls on roofs, roads and car parks, it runs off much faster than on meadows or woodland. Without countermeasures, large volumes of water reach the sewer system in a short time, and it is not designed for this everywhere. The consequences are backflow, flooded basements and, in combined systems, discharges of untreated wastewater into watercourses.
Retention breaks this peak flow. The water is collected in a storage unit and passed on through a flow restrictor only in the quantity that the downstream network can cope with. After the rain, the storage gradually empties until it is ready again for the next event.
Types of retention system
Common on properties are underground retention tanks made of concrete or plastic, enlarged chambers with a flow control device, and large-diameter storage pipes that also serve as storage. Above ground, swales, shallow depressions on green spaces or car parks and green retention roofs are used.
Retention is often combined with infiltration: part of the water infiltrates and the rest drains away at a restricted rate. On a larger scale, municipalities operate stormwater tanks and storage sewers in the public network. What matters for the property, however, is its own system, which the owner must maintain.
When does the municipality require retention?
Whether retention is needed, and to what extent, is set out in the general drainage plan (GEP) and the wastewater regulations. The municipality often sets a maximum permissible discharge that a plot may release into the sewer system or a watercourse during rain. Anything above that has to be held back on the plot.
Sizing and construction follow the VSA guideline ‘Wastewater management in wet weather’ and SN 592 000. The specific values vary locally; the designer obtains them from the building department. With climate change and more frequent heavy rain, many municipalities are placing more emphasis on retention and sponge city measures.
The flow restrictor: a small component with a big effect
The heart of every retention system is the flow control device – an orifice plate, a vortex flow control or a gate valve that limits the outflow. If the restrictor is blocked, the storage fills up and eventually overflows, even though the system would be large enough. If it has been removed or tampered with, the system loses its effect and the network once again receives the full peak.
Because flow restrictors have small openings, leaves, sand and litter readily collect in front of them. An upstream silt trap and regular checks are therefore crucial. After every major storm, it is worth taking a look into the restrictor chamber.
Cleaning and maintenance
Retention tanks and storage chambers collect sediment with every rainfall. Over time this reduces the usable volume and causes odours. A combined jetting and vacuum vehicle removes the sludge, and the inlet and outlet pipes are jetted at high pressure and checked by camera if necessary.
A fixed maintenance schedule with checks of the flow restrictor, emergency overflow, inlet and silt trap makes sense. In condominium ownership or commercial properties in particular, the system is otherwise quickly forgotten until the first heavy rain floods the underground car park.
A housing development in Dübendorf had an underground retention tank beneath the playground. During a summer thunderstorm, water suddenly appeared in the underground car park entrance. The inspection revealed that a plug of leaves and gravel had formed in front of the orifice plate; the tank was full and the emergency overflow was backing up. The team vacuumed out the tank and silt trap, jetted the flow restrictor clear and checked the outlet pipe by camera. The property management company has since included the inspection in the annual maintenance schedule.