What is a vent pipe?
When wastewater flows down a soil stack, it pushes a column of air ahead of it and draws air in behind it. If this air cannot flow in freely, pressure differences arise. The vent pipe therefore connects the soil stack with the outside air, usually by extending the stack at the same diameter up above the roof.
This main vent is the norm. There are also secondary vents and branch vents that create additional air paths, for example in very tall buildings or with long branch pipes. Designers determine which solution is needed according to SN EN 12056 and SN 592 000, based on building height, connections and flow rates.
What is venting for?
Its most important task is protecting the traps. Without venting, the negative pressure of a larger discharge pulls the seal water out of the traps of drains lower down. After that, the way is open for sewer gases. Conversely, positive pressure can push water and air out of the traps.
The vent pipe also ensures an even, steady flow and carries gases from the sewer system away above the roof, where they are diluted. This is not just a question of odour: gases such as hydrogen sulphide form in wastewater, which are harmful to health in higher concentrations and attack pipes and manholes.
Air admittance valves as an alternative
Where a pipe above the roof is not possible, for example in conversions or attic floors, air admittance valves are used. They open under negative pressure and let room air into the pipe, but close under positive pressure so that no gases escape. They therefore only balance negative pressure and do not replace a main vent in every case.
Air admittance valves must remain accessible and in working order. Stuck or dirty membranes are a common cause of gurgling and odours. Whether and where they are permitted is governed by the standards; at least one main vent above the roof is generally still required.
Signs of a blocked vent pipe
Typical signs are gurgling noises in the washbasin, shower or WC when water drains elsewhere in the house, and a drain smell that comes and goes. Noticeably slow drainage along the whole stack can also point to inadequate venting, even though the pipe itself is clear.
Causes include birds’ nests, leaves, insects, ice in winter, crushed roof penetrations or, after conversions, vent pipes that have been cut off and sealed. In older houses, stack vents were sometimes simply covered over during roof renovations.
Inspection and cleaning
A vent pipe can be surveyed with a camera from above via the roof opening or from below via a rodding eye. This shows whether it is continuous, where an obstruction is located and whether it was interrupted during a conversion. Blockages are removed with a drain snake or by jetting.
During roof work, the roofer should mark the vent pipes and not seal them. A bird guard makes sense but must not significantly reduce the cross-section. With recurring drain smells, the vent is always one of the first things to check.
In an apartment building in St. Gallen, the tenants on the ground floor complained of a drain smell whenever someone upstairs took a shower. The traps were in order. The survey of the soil stack from the rodding eye in the basement showed a clear wastewater pipe, but in the attic the pipe came to a dead end: during an attic conversion, the stack vent had been cut off and sealed. After the vent above the roof was restored, the traps stayed full and the smell no longer occurred.