GlossaryDrainage technical term

Fragmentation (shattered pipe)

Also: Shattered pipe, Broken pipe with fragments

Fragmentation refers to a wastewater pipe that does not just have a single crack but has broken into several pieces. The fragments still lie roughly in their original position but are only supported by the surrounding soil. This finding is one of the most serious defects a CCTV drain survey can reveal.

Camera inspection of a sewer pipe to detect cracks and fragmentation

In brief

Fragmentation is serious pipe damage in which the wall of a wastewater pipe has broken into individual pieces through several cracks. The fragments are only held in place by the soil. There is a risk of collapse, wastewater escapes and soil gets in. Depending on stability, the pipe is rehabilitated trenchlessly with a CIPP liner or replaced using open-cut construction.

What does fragmentation mean?

A wastewater pipe can be damaged in various ways: with a fine hairline crack, a continuous longitudinal crack, a displaced joint or a hole. When several longitudinal and circumferential cracks meet, the pipe wall is broken up into separate pieces. These pieces are called fragments, and the damage is known as fragmentation or a shattered pipe.

In the camera image you can see a network of cracks dividing the wall into segments. The edges are often slightly offset from each other, sometimes individual fragments are already missing and soil is visible behind them. In damage coding according to SN EN 13508-2, the condition is recorded as a break or collapse, stating its extent.

How does fragmentation occur?

Fragmentation is almost always the end of a long history of damage. It begins with individual cracks caused by overloading, settlement or material ageing. Water escapes or enters through these cracks and washes fine material out of the pipe bedding. The pipe loses its lateral support, the load becomes concentrated and further cracks form.

Brittle materials laid decades ago, such as vitrified clay, unreinforced concrete, cement and fibre cement, are particularly vulnerable. High traffic loads with shallow cover, roots widening cracks and freeze-thaw cycles in pipes close to the surface accelerate the deterioration. A single overload, for example from heavy construction machinery, can also be the tipping point for a pipe that is already weakened.

Why the finding is urgent

A fragmented pipe no longer supports itself. If the ground stays undisturbed it may hold for a while, but any disturbance can tip the fragments into the pipe. The flow is then blocked and water backs up into the building. Wastewater also escapes into the ground, polluting soil and groundwater.

Conversely, soil is washed into the sewer. Voids can form above the pipe, which show up as subsidence in the lawn, the forecourt or the road surface. According to the VSA guideline ‘Maintenance of sewer systems’, fragmentation generally results in one of the worst condition grades, indicating that action is needed in the short term.

Caution when cleaning

Caution is needed with a fragmented pipe. High-pressure water jetting at full power or a heavy mechanical tool can tear out loose fragments and trigger a collapse. Experienced specialists therefore adjust the pressure and tool and work under camera supervision.

Anyone who finds fragmentation during an inspection should treat the pipe gently until it is rehabilitated: no further heavy loads above the pipe, no aggressive cleaning attempts and prompt planning of the repair.

Rehabilitation: trenchless or open-cut?

Whether a fragmented pipe can be rehabilitated trenchlessly depends on how stable the fragments still are. If they are largely in position and the cross-section is clear, a CIPP liner can be installed. Once cured, it forms an independent, load-bearing pipe within the old pipe and does not depend on the strength of the fragments.

For short defects, a patch liner may be enough. If fragments have already shifted, large pieces are missing or the pipe has collapsed, only replacement using open-cut construction or a method such as pipe bursting is an option. The decision is made on the basis of the camera images; after rehabilitation, a leak-tightness test confirms the result.

Practical example

During a pre-sale inspection of a property in Zug, the camera revealed pronounced fragmentation over a length of about two metres in the old cement pipe under the driveway. The block paving above it had already subsided slightly. Because the fragments were still in position, the pipe was cleaned gently and rehabilitated with a CIPP liner. The driveway did not have to be broken up, and the leak-tightness test proved that the pipe was watertight.

Fragmentation (shattered pipe): frequently asked questions

How urgent is fragmentation?+

Very urgent. A fragmented pipe no longer supports itself and can collapse at any time. Rehabilitation should be planned promptly to avoid backflow, ground subsidence and escaping wastewater.

Can a fragmented pipe still be rehabilitated with a CIPP liner?+

Often yes, if the fragments are still in position and the cross-section is clear. The CIPP liner forms its own load-bearing pipe. If parts have shifted or collapsed, replacement is necessary.

Can a fragmented pipe be jetted?+

Only with care and adjusted pressure. Powerful high-pressure jetting can tear out loose fragments. Specialists clean such pipes gently and under camera supervision.

How does fragmentation occur?+

Usually over years: individual cracks let water escape, the bedding is washed out, the pipe loses its support and breaks into several pieces. Old, brittle pipe materials and high loads accelerate this.