What is thermography in leak detection?
Thermography is the contact-free measurement of surface temperatures with an infrared or thermal imaging camera. Depending on its temperature, every object emits thermal radiation that is invisible to the human eye. The camera captures this radiation and converts it into a false-colour image: warm areas typically appear yellow, orange or white, cool areas blue or violet.
In leak detection, this effect is used deliberately. When warm water flows through a pipe, it heats the surrounding material – the screed, the plaster or the tiles. If the water escapes at a leaking point, the heat spreads out over an area there. The thermal image then shows a characteristic warm patch that is clearly different from the narrow, linear heat trace of the intact pipe.
Thermography is therefore one of several leak detection methods. Karo Kanaltechnik uses it alongside acoustic location with ground microphones and a correlator, the tracer gas method and the CCTV drain survey. It is rarely used on its own, but usually as a quick first overview that narrows down the search area.
How the thermal image works
A thermal imaging camera only measures the surface, not the inside of a wall or floor. What it shows is the heat that has travelled from the pipe through the material to the surface. The decisive factor is therefore the temperature difference: the more clearly the pipe or the escaped water stands out from its surroundings, the clearer the image.
To create this contrast, the affected system is deliberately heated up before the measurement – for example by turning up the heating, running underfloor heating for longer or drawing hot water for a certain time. Depending on the floor build-up, the heat needs some time to pass through the screed and floor covering to the surface. A thin tile conducts heat faster than a thick parquet or carpet build-up.
The emissivity of the surface is also important. Matt materials such as plaster, concrete or tiles are easy to measure. Shiny surfaces such as stainless steel, bare copper or glass, on the other hand, reflect the heat of their surroundings and can produce a misleading image. An experienced specialist takes these influences into account when evaluating the images and does not interpret every coloured patch as a leak.
When thermography works well on pipes
Thermography is at its most effective on pipes that carry warm water. These include hot water pipes and circulation pipes in bathrooms and kitchens, heating pipes to the radiators and, above all, underfloor heating. Because these pipes are much warmer than the room, they show up clearly in the thermal image.
With underfloor heating, the thermal image makes the heating coils in the screed visible. A leak appears as a warm zone that does not follow the regular pattern of the heating pipes. A typical sign of such a leak is a heating system that repeatedly needs topping up with water because the pressure drops.
Thermography is also suitable for pipe locating: anyone who wants to know before a renovation where heating or hot water pipes run in the floor or wall can trace their route with the thermal imaging camera. This allows holes to be drilled and chases to be cut without hitting a pipe. The spread of moisture after water damage can also be roughly mapped with the thermal image, because wet areas are usually cooler than dry ones due to evaporation.
When thermography does not help
Without a temperature difference, there is no meaningful thermal image. Cold water pipes often have almost the same temperature as the wall they are in. A leak in a cold water pipe can therefore only be detected indirectly by thermography, for example through the evaporative cooling of a damp area – and even then only if the moisture reaches the surface.
With wastewater pipes, the method usually reaches its limits. Wastewater only flows intermittently and cools quickly in the pipe; underground drains also lie beneath the floor slab or in the ground, where the heat hardly reaches the surface. For leaking wastewater pipes, the CCTV drain survey, the leak-tightness test with air or water (test procedure in accordance with SN EN 1610) or a smoke test are the more reliable options.
Deep-lying pipes, thick floor build-ups, insulation layers, carpets or furniture that has stood on the floor for a long time also distort or obscure the image. The same applies to external influences such as direct sunlight, draughts, underfloor heating that warms other zones at the same time, or freshly mopped floors. In such cases, a second method is indispensable.
Combination with acoustics, tracer gas and camera
In practice, thermography is rarely the only tool. The thermal image often narrows the area down to a few square metres, and a second method confirms the exact spot. Only this combination makes it possible to open up only where the leak actually is.
With pressure pipes, acoustic location complements the thermal image: escaping water creates a noise that is picked up with ground microphones or a correlator. For small or hard-to-hear leaks, tracer gas is used – usually forming gas, a mixture of nitrogen and a small proportion of hydrogen. The gas escapes at the leaking point and is detected at the surface with a sensitive detector.
With wastewater pipes, the camera takes the leading role. The CCTV drain survey shows cracks, displaced joints or root ingress directly from the inside and documents the condition in accordance with SN EN 13508-2. The leak-tightness test then answers the question of whether a pipe section is watertight. Which methods make sense in which order depends on the type of pipe, accessibility and the pattern of damage.
How thermographic leak detection works
It starts with a preliminary assessment: which pipe is affected – hot water, cold water, heating or wastewater? Is the water meter still registering consumption even though all taps are closed? Is the heating pressure dropping? Where are there signs of moisture, stains or mould? Existing plans help to estimate the route of the pipes.
The system is then prepared. The heating or hot water is operated so that there is a clear temperature difference to the surroundings, and sources of interference such as open windows or direct sunlight are eliminated. Where necessary, furniture and carpets above the suspected area are removed.
Next, the specialist takes overview images of the room before moving on to detailed images. Unusual warm zones are checked with a second method, and the leak is marked on the floor or wall and documented with photos and thermal images. At Karo, clients receive a report after the leak has been located, with the position of the leak and a recommendation for the repair.
Only then is anything opened up – and only at the marked spot. After the repair, a further pressure or leak-tightness test confirms that the pipe is watertight again.
Limitations and typical sources of error
A thermal image is not an X-ray. It only shows what reaches the surface, and the heat spreads out on the way there. That is why the warm zone in the image is often larger than the actual leak, and the centre of the zone is not necessarily exactly above the leaking point. Water can also travel along pipes, insulation or layers and show up far away from the leak.
Sources of error include reflections on shiny surfaces, an incorrectly set emissivity, different floor coverings in the same room, thermal bridges in the building envelope and appliances that give off heat themselves – such as fridges, water heaters or electrical distribution boards. A reliable conclusion therefore only emerges from evaluating several images under controlled conditions and cross-checking them with a second measurement method.
Thermography on a house: leak detection or building thermography?
People searching for «thermography house» often mean building thermography. It shows heat losses through the building envelope, leaky windows and thermal bridges and is used for energy assessments, usually in the cold season when there is a large difference between indoor and outdoor temperatures. The right people to contact for this are energy consultants.
Thermography in leak detection pursues a different goal: it does not look for heat losses, but for pipes and escaping water inside the building. The technology is the same, but preparation and evaluation differ considerably. If you are dealing with a leaking pipe, falling heating pressure or unexplained water damage, leak detection with combined methods is the right approach.
This is what a typical job looks like: in a single-family home in the Zurich Oberland, the heating has to be topped up every few weeks, and a spot in the living room parquet feels unusually warm. To locate the leak, the underfloor heating is run at a high flow temperature for a few hours. The thermal image shows the regular heating coils and next to them a shapeless warm zone that does not fit the pattern. The spot is confirmed with tracer gas and marked on the floor. Instead of breaking open the whole room, only a small piece of parquet and screed is opened, the heating pipe is repaired and the system is then checked with a pressure test.
